Reversible Flow Fan 92x38mm 9238 12v Dc Axial Cooling Fan
Product Details
| Customized Support: | OEM, ODM | Electric Current Type: | DC |
|---|---|---|---|
| Mounting Type: | Free Standing | Blade Material: | Plastic |
| Voltage: | 05-48v | Warranty: | 1 Year |
| After-sales Service Provided: | Online Support | Product Name: | DC Brussless Fan |
| Application: | Computer | Size: | 92*92*38 |
| Usage: | Cooling System | Name: | Commercial Axial Wall Fan |
| Bearing Type: | Dual Ball Bearing | Material: | Plastic Blade |
| Product Type: | Air Delivery | Color: | Balck |
| Item: | Cooing Fans | Type: | Axial Flow Fan |
| Applicable Industries: | Manufacturing Plant, Machinery Repair Shops, Food & Beverage Factory, Farms, Restaurant, Home Use |
Product Description




|
Air volume and pressure:
There are two methods for measuring air volume and pressure, one is using a wind tunnel test, and the other is using a double box method. But for the average user, there is no such device. It can only be based on the data provided by the manufacturer as a reference, and ultimately depends on the cooling effect.
Air volume: Air volume refers to the product of the plane speed of the ventilation area of the fan. The ventilation area is the exit area minus the projected area at the tongue. Plane velocity is the velocity of gas moving through the entire plane in m3 / s. When the plane speed is constant, the larger the outer diameter of the fan impeller, the larger the ventilation area, and the larger the air volume. Plane speed is determined by the speed and wind pressure of the rotor. When the ventilation area is constant, the greater the plane speed, the greater the air volume. The greater the amount of air, the greater the heat absorbed by the air. When the air flows and transfers, it can carry more heat around it, and the more obvious the fan heat effect is.
Wind pressure: For normal ventilation, the resistance in the ventilation stroke of the fan must be overcome. The fan must generate pressure to overcome the resistance of the air supply. The measured pressure change is called static pressure, which is the differential pressure between the maximum static pressure and atmospheric pressure. It is the pressure of the gas acting parallel to the surface of the object, and the static pressure is measured through a hole perpendicular to its surface. The conversion of the kinetic energy required in the gas flow into a form of pressure is called dynamic pressure.
To achieve the purpose of air supply, static pressure and dynamic pressure are required. Total pressure is the algebraic sum of static pressure and dynamic pressure. Total pressure refers to the total pressure increase given by the fan, that is, the difference between the total pressure between the fan's outlet and the inlet. In practical applications, the nominal maximum air volume value is not the actual air supply volume obtained by the fan fan. The large air volume does not mean that the ventilation capacity is strong. When the air is flowing, the air flow will encounter the interference of the fan thermal element or the component in its flow path, and its impedance will restrict the free flow of air. That is, when the air volume increases, the wind pressure decreases. Therefore, there must be an operating point, that is, the intersection of the fan performance curve and the wind resistance curve. At the operating point, the slope of the fan characteristic curve is the smallest, and the change rate of the system characteristic curve is the lowest. Note that the fan's static efficiency (air volume × wind pressure ÷ power consumption) at this time is better. Of course, in order to reduce the system impedance, even a smaller fan can be used to obtain the same air volume. |






Product Highlights
Product Description Air volume and pressure: There are two methods for measuring air volume and pressure, one is using a wind tunnel test, and the other is using a double box method. But for the average user, there is no such device. It can only be based on the data provided by the manufacturer as a ...
Factory Directly 5015 5215 Fan Blowers 50x50x15mm 5v 12v 24v Mini Dc Centrifugal Blower With Fan Price
Products Description Speed: 3500 - 6500RPM Airflow: 10.55 - 19.35 CFM Pressure: 2.12 - 7.12mmAq Noise: 21.5 - 35.6 dBA Voltage: 05 - 24V Motor : DC Brushless external rotor motor Frame: PBT (Fiberglass reinforced plastic,PBT housing) Impeller: PBT Bearing System: 2 Ball,Longlife sleeve ,FDB ...
25mm Ball Bearing 2pin Mini Cooler Fan 25x25x10mm 2510 Brushless Cooling Fan Dc Axial Cooling Fan Silent 5v 12v 24v
Products Description Speed: 6500 - 12000 RPM Airflow: 1.31-2.29CFM Pressure: 2.06-6.34 mmAq Noise: 18.2-24.3dBA Voltage: 05v -- 12V Motor : DC Brushless external rotor motor Frame: PBT Impeller: PBT Bearing System: 2 Ball,Longlife sleeve ,FDB Insulation: Class A Operation Temperture: -10℃...
Dc Axial Flow Fan 9225 Industrial Control Equipment Cabinet Cooling Fan Factory Wholesale
Product Description Specification item value Type Axial Flow Fan Applicable Industries Manufacturing Plant, Machinery Repair Shops, Food & Beverage Factory, Farms, Restaurant, Home Use, Retail, Printing Shops, Construction works , Energy & Mining, Other, Advertising Company Customized support OEM, ...
OEM High CFM Dual Ball Bearing 200mm EC Axial Flow Fan
Products Description Specifications 200X200X60 mm Speed: 1600-3400 RPM Voltage: 12-48V Airflow: 328.27-656.54 cfm Pressure: 7.47-29.89 mmAq Noise: 40.6-64.5 dBA Motor : DC Brushless external rotor motor Frame: Aluminum Impeller: PBT Bearing System: 2 Ball Insulation: Class A Operation Temperture: ...
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.